FCMF/FCVF-A Series

Daikin’s FCMF/VF range of cassette air conditioners are designed to redefine air conditioning with 360⁰ airflow that cools the entire room to ensure comfort that never feels cold. Its revolutionary uniform air distribution guarantees comfort that spreads more widely. Besides this, the unit boasts of some of the amazing features that make it a perfect choice for summers.

Categories: ,

Description

Round Flow Cassette Cooling Only – 5 Star Inverter R-32 (FCMF-Series)

inverter-5star-r32
Model Indoor unit FCMF50ARV169 FCMF71ARV169 FCMF90ARV169 FCMF100ARV169
Outdoor unit RZMF50BRV169 RZMF71BRV169 RZMF90BRV169 RZMF100BRV169
Remote Wireless Optional BRC91A152
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code With Sensing BYCQ125EEF6
Power supply 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph
Cooling capacity -Rated (min ~max) kW 5.27(3.2~5.6) 7.1 (3.2~8.0) 8.79 (4.5~10.1) 10.51 (5.0~11.2)
Power consumption Cooling-Rated kW 1.36 1.90 2.42 3.10
Annual Power Consumption kWh 784.56 1057.11 1365.2 1804.81
ISEER / Stars Wh/Wh 5.2/5 Star 5.2/5 Star 5.1/5 Star 4.51/5 Star
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 23 / 21 / 18.5 / 16 / 13.5 34.5 / 31 / 27.5 / 24 / 20
cfm 812/742/653/565/477 1218/1095/971/848/706
Sound level (H/HM/M/ML/L) dB(A) 37 / 34.5 / 32 / 29.5 / 27.5 45 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD) Unit mm 256X840X840 298X840X840
Panel mm 50X950X950
Machine weight Unit kg 22 25
Panel kg 5.5
Drain mm VP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour Ivory White
Compressor Type Hermetically Sealed Swing Type
Motor output kW 1.3 1.3 1.6 1.6
Refrigerant R32
Refrigerant charge kg 1.09 1.3 2.8 2.8
Sound level Cooling dB(A) 48 50 51 51
Dimensions (HXWXD) mm 595x845x300 595x845x300 990x940x320 990x940x320
Machine weight kg 36.5 40 57 57
Certified operation range °CDB 21 ~ 52
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Max. interunit piping length m 30 30 50 50
Max. installation level difference m 20 20 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Cassette Cooling Only – 5 Star Inverter R-32 (FCMF-Series)

inverter-r32
Model Indoor unit FCMF125ARV169 FCMF125ARV169 FCMF140ARV169 FCMF140ARV169
Outdoor unit RZMF125BRV169 RZMF125BRY169 RZMF140BRV169 RZMF140BRY169
Remote Wireless Optional BRC91A152
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code With Sensing BYCQ125EEF6
Power supply 230V/50Hz/1ph 400V/50Hz/3ph 230V/50Hz/1ph 400V/50Hz/3ph
Cooling capacity -Rated (min ~max) kW 12.5 (5.7~14.0) 12.5 (5.7~14.0) 14.0 (6.2~15.5) 14.0 (6.2~15.5)
Power consumption Cooling-Rated kW 4.26 4.08 4.95 4.95
Annual Power Consumption kWh 2359.13 2330.02 2644.86 2644.86
ISEER / Stars Wh/Wh 4.10/5 Star 4.15/5 Star 4.1/5 Star 4.1/5 Star
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 36.5/33/29/25/21
cfm 1288/1165/1024/882/741
Sound level (H/HM/M/ML/L) dB(A) 46/43/40/36/32.5
Dimensions (HXWXD) Unit mm 298X840X840
Panel mm 50X950X950
weight Unit kg 25
Panel kg 5.5
Drain mm VP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour Ivory White
Compressor Type Hermetically Sealed Swing Type
Motor output kW 2.4 2.4 2.4 2.4
Refrigerant R32
Refrigerant charge kg 3.1 3.1 3.1 3.1
Sound level Cooling dB(A) 55 55 55 55
Dimensions (HXWXD) mm 990x940x320 990x940x320 990x940x320 990x940x320
Machine weight kg 69 69 69 69
Certified operation range °CDB 21 ~ 52
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Max. interunit piping length m 50 50 50 50
Max. installation level difference m 30 30 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Cassette Cooling Only – 4 Star Inverter R-32 (FCVF-Series)

inverter-4star-r32
Model Indoor unit FCVF50ARV169 FCVF71ARV169 FCVF90ARV169 FCVF100ARV169
Outdoor unit RZVF50BRV169 RZVF71BRV169 RZVF90BRV169 RZVF100BRV169
Remote Wireless Optional BRC91A152
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code With Sensing BYCQ125EAF6
Power supply 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph 230V/50Hz/1ph
Cooling capacity -Rated (min ~max) kW 5.27 (3.2~5.6) 7.1 (3.2~8.0) 9.0 (4.5~10.1) 10.51 (5.0~11.2)
Power consumption Cooling-Rated kW 1.45 2.01 2.51 3.26
Annual Power Consumption kWh 842.77 1133.54 1436.16 2057.73
ISEER / Stars Wh/Wh 4.85/4 Star 4.85/4 Star 4.85/4 Star 3.95/4 Star
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 23 / 21 / 18.5 / 16 / 13.5 34.5 / 31 / 27.5 / 24 / 20
cfm 812/742/653/565/477 1218/1095/971/848/706
Sound level (H/HM/M/ML/L) dB(A) 37 / 34.5 / 32 / 29.5 / 27.5 45 / 41.5 / 38 / 35 / 32.5
Dimensions (HXWXD) Unit mm 256X840X840 298X840X840
Panel mm 50X950X950
Weight Unit kg 22 25
Panel kg 5.5
Drain mm VP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour Ivory White
Compressor Type Hermetically Sealed Swing Type
Motor output kW 1.3 1.3 1.6 1.6
Refrigerant R32
Refrigerant charge kg 1.09 1.3 2.8 2.8
Sound level Cooling dB(A) 48 50 51 51
Dimensions (HXWXD) mm 595x845x300 595x845x300 990x940x320 990x940x320
Machine weight kg 36.5 40 57 57
Certified operation range °CDB 21 ~ 52
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Max. interunit piping length m 30 30 50 50
Max. installation level difference m 20 20 30 30

Note :

  • Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
  • Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  • Star rating is applicable for single phase units upto a rated cooling capacity of 10,465 Watts as defined by Bureau of Energy Efficiency, Ministry of Power.

Round Flow Cassette Cooling Only – 4 Star Inverter R-32 (FCVF-Series)

inverter-r32
Model Indoor unit FCVF125ARV169 FCVF125ARV169 FCVF140ARV169 FCVF140ARV169
Outdoor unit RZVF125BRV169 RZVF125BRY169 RZVF140BRV169 RZVF140BRY169
Remote Wireless Optional BRC91A152
Signal Receiver Unit -Model Number BRC7M632F-6
Wired Optional BRC1E63
Panel Code With Sensing BYCQ125EAF6
Power supply 230V/50Hz/1ph 400V/50Hz/3ph 230V/50Hz/1ph 400V/50Hz/3ph
Cooling capacity -Rated (min ~max) kW 12.5 (5.7~14.0) 12.5 (5.7~14.0) 14.0 (6.2~15.5) 14.0 (6.2~15.5)
Power consumption Cooling-Rated kW 4.45 4.45 5.25 5.12
Annual Power Consumption kWh 2513.48 2513.48 2886.34 2852.03
ISEER / Stars Wh/Wh 3.85/4 Star 3.85/4 Star 3.75/4 Star 3.80/4 Star
Indoor unit
Colour Galvanized Steel Plate
Airflow rate (H/HM/M/ML/L) m3/min 36.5/33/29/25/21
cfm 1288/1165/1024/883/742
Sound level (H/HM/M/ML/L) dB(A) 46/43/40/36/32.5
Dimensions (HXWXD) Unit mm 298X840X840
Panel mm 50X950X950
weight Unit kg 25
Panel kg 5.5
Drain mm VP25 (I.D. ⌀ 25, O.D. ⌀ 32)
Outdoor unit
Colour Ivory White
Compressor Type Hermetically Sealed Swing Type
Motor output kW 2.4 2.4 2.4 2.4
Refrigerant R32
Refrigerant charge kg 3.1 3.1 3.1 3.1
Sound level Cooling dB(A) 55 55 55 55
Dimensions (HXWXD) mm 990x940x320 990x940x320 990x940x320 990x940x320
Machine weight kg 69 69 69 69
Certified operation range °CDB 21 ~ 52
Piping connections Liquid (Flare) mm 9.52
Gas (Flare) mm 15.88
Max. interunit piping length m 50 50 50 50
Max. installation level difference m 30 30 30 30

Reviews

There are no reviews yet.

Be the first to review “FCMF/FCVF-A Series”

Your email address will not be published. Required fields are marked *